434 found, showing page 7 of 11

200A LOAD CENTER
Square D Homeline convertible main breaker load center. For residential and commercial power distribution. Plug-on Neutral ready and built with a plated, aluminum bus bar that is tested and listed only for Homeline circuit breakers. 200 amp main breaker included. Engineered for fast installation and wire savings. UL (Underwriter's Laboratories) listed for residential and commercial power distribution.
View Details
Square D Homeline convertible main breaker load center. For residential and commercial power distribution. Plug-on Neutral ready and built with a plated, aluminum bus bar that is tested and listed only for Homeline circuit breakers. 200 amp main breaker included. Engineered for fast installation and wire savings. UL (Underwriter's Laboratories) listed for residential and commercial power distribution.

50A NON CART FUSE
General-purpose one-time, NON cartridge fuse. For use in non-current limiting lighting circuits, main panel protections, or other circuits that do not contain large electric motors. No time delay. UL (Underwriter's Laboratories) listed Class K5 (50,000 AIR) with ferrule ends. 250V.
View Details
General-purpose one-time, NON cartridge fuse. For use in non-current limiting lighting circuits, main panel protections, or other circuits that do not contain large electric motors. No time delay. UL (Underwriter's Laboratories) listed Class K5 (50,000 AIR) with ferrule ends. 250V.

60A NON CART FUSE
General-purpose one-time, NON cartridge fuse. For use in non-current limiting lighting circuits, main panel protections, or other circuits that do not contain large electric motors. No time delay. UL (Underwriter's Laboratories) listed Class K5 (50,000 AIR) with ferrule ends. 250V.
View Details
General-purpose one-time, NON cartridge fuse. For use in non-current limiting lighting circuits, main panel protections, or other circuits that do not contain large electric motors. No time delay. UL (Underwriter's Laboratories) listed Class K5 (50,000 AIR) with ferrule ends. 250V.

FUSE CART FRNR15
Heavy-duty Fusetron, dual element, time delay FRN-R cartridge fuse for motor protection. Helps protect motors from burnout caused by overloads or single phasing. Time delay feature allows the initial startup surge for typical motors to pass, but opens prior to burnout when longer dangerous overloads are present. UL (Underwriter's Laboratories) listed Class R 200,000 AIR (amp interrupting rating). 1/10A to 60A have ferrule ends, 70A to 200A have knife-blade ends. 250V.
View Details
Heavy-duty Fusetron, dual element, time delay FRN-R cartridge fuse for motor protection. Helps protect motors from burnout caused by overloads or single phasing. Time delay feature allows the initial startup surge for typical motors to pass, but opens prior to burnout when longer dangerous overloads are present. UL (Underwriter's Laboratories) listed Class R 200,000 AIR (amp interrupting rating). 1/10A to 60A have ferrule ends, 70A to 200A have knife-blade ends. 250V.

*20A HDTD FUSE CARTRIDGE
Heavy-duty Fusetron, dual element, time delay FRN-R cartridge fuse for motor protection. Helps protect motors from burnout caused by overloads or single phasing. Time delay feature allows the initial startup surge for typical motors to pass, but opens prior to burnout when longer dangerous overloads are present. UL (Underwriter's Laboratories) listed Class R 200,000 AIR (amp interrupting rating). 1/10A to 60A have ferrule ends, 70A to 200A have knife-blade ends. 250V.
View Details
Heavy-duty Fusetron, dual element, time delay FRN-R cartridge fuse for motor protection. Helps protect motors from burnout caused by overloads or single phasing. Time delay feature allows the initial startup surge for typical motors to pass, but opens prior to burnout when longer dangerous overloads are present. UL (Underwriter's Laboratories) listed Class R 200,000 AIR (amp interrupting rating). 1/10A to 60A have ferrule ends, 70A to 200A have knife-blade ends. 250V.

*25A HDTD FUSE CARTRIDGE
Heavy-duty Fusetron, dual element, time delay FRN-R cartridge fuse for motor protection. Helps protect motors from burnout caused by overloads or single phasing. Time delay feature allows the initial startup surge for typical motors to pass, but opens prior to burnout when longer dangerous overloads are present. UL (Underwriter's Laboratories) listed Class R 200,000 AIR (amp interrupting rating). 1/10A to 60A have ferrule ends, 70A to 200A have knife-blade ends. 250V.
View Details
Heavy-duty Fusetron, dual element, time delay FRN-R cartridge fuse for motor protection. Helps protect motors from burnout caused by overloads or single phasing. Time delay feature allows the initial startup surge for typical motors to pass, but opens prior to burnout when longer dangerous overloads are present. UL (Underwriter's Laboratories) listed Class R 200,000 AIR (amp interrupting rating). 1/10A to 60A have ferrule ends, 70A to 200A have knife-blade ends. 250V.

30A CARTRIDGE FUSE
Heavy-duty Fusetron, dual element, time delay FRN-R cartridge fuse for motor protection. Helps protect motors from burnout caused by overloads or single phasing. Time delay feature allows the initial startup surge for typical motors to pass, but opens prior to burnout when longer dangerous overloads are present. UL (Underwriter's Laboratories) listed Class R 200,000 AIR (amp interrupting rating). 1/10A to 60A have ferrule ends, 70A to 200A have knife-blade ends. 250V.
View Details
Heavy-duty Fusetron, dual element, time delay FRN-R cartridge fuse for motor protection. Helps protect motors from burnout caused by overloads or single phasing. Time delay feature allows the initial startup surge for typical motors to pass, but opens prior to burnout when longer dangerous overloads are present. UL (Underwriter's Laboratories) listed Class R 200,000 AIR (amp interrupting rating). 1/10A to 60A have ferrule ends, 70A to 200A have knife-blade ends. 250V.

*35A HDTD FUSE CARTRIDGE
Heavy-duty Fusetron, dual element, time delay FRN-R cartridge fuse for motor protection. Helps protect motors from burnout caused by overloads or single phasing. Time delay feature allows the initial startup surge for typical motors to pass, but opens prior to burnout when longer dangerous overloads are present. UL (Underwriter's Laboratories) listed Class R 200,000 AIR (amp interrupting rating). 1/10A to 60A have ferrule ends, 70A to 200A have knife-blade ends. 250V.
View Details
Heavy-duty Fusetron, dual element, time delay FRN-R cartridge fuse for motor protection. Helps protect motors from burnout caused by overloads or single phasing. Time delay feature allows the initial startup surge for typical motors to pass, but opens prior to burnout when longer dangerous overloads are present. UL (Underwriter's Laboratories) listed Class R 200,000 AIR (amp interrupting rating). 1/10A to 60A have ferrule ends, 70A to 200A have knife-blade ends. 250V.

*50A HDTD FUSE CARTRIDGE
Heavy-duty Fusetron, dual element, time delay FRN-R cartridge fuse for motor protection. Helps protect motors from burnout caused by overloads or single phasing. Time delay feature allows the initial startup surge for typical motors to pass, but opens prior to burnout when longer dangerous overloads are present. UL (Underwriter's Laboratories) listed Class R 200,000 AIR (amp interrupting rating). 1/10A to 60A have ferrule ends, 70A to 200A have knife-blade ends. 250V.
View Details
Heavy-duty Fusetron, dual element, time delay FRN-R cartridge fuse for motor protection. Helps protect motors from burnout caused by overloads or single phasing. Time delay feature allows the initial startup surge for typical motors to pass, but opens prior to burnout when longer dangerous overloads are present. UL (Underwriter's Laboratories) listed Class R 200,000 AIR (amp interrupting rating). 1/10A to 60A have ferrule ends, 70A to 200A have knife-blade ends. 250V.

60A CARTRIDGE FUSE
Heavy-duty Fusetron, dual element, time delay FRN-R cartridge fuse for motor protection. Helps protect motors from burnout caused by overloads or single phasing. Time delay feature allows the initial startup surge for typical motors to pass, but opens prior to burnout when longer dangerous overloads are present. UL (Underwriter's Laboratories) listed Class R 200,000 AIR (amp interrupting rating). 1/10A to 60A have ferrule ends, 70A to 200A have knife-blade ends. 250V.
View Details
Heavy-duty Fusetron, dual element, time delay FRN-R cartridge fuse for motor protection. Helps protect motors from burnout caused by overloads or single phasing. Time delay feature allows the initial startup surge for typical motors to pass, but opens prior to burnout when longer dangerous overloads are present. UL (Underwriter's Laboratories) listed Class R 200,000 AIR (amp interrupting rating). 1/10A to 60A have ferrule ends, 70A to 200A have knife-blade ends. 250V.

*FUSE ELECTRONIC
Fast acting AGC glass tube electronic fuse for use with cordless phones, stereo speakers, CB radios, electric fences. 1-1/4" L. x 1/4" diameter, 250V. UL listed. Individually bagged.
View Details
Fast acting AGC glass tube electronic fuse for use with cordless phones, stereo speakers, CB radios, electric fences. 1-1/4" L. x 1/4" diameter, 250V. UL listed. Individually bagged.

2" HUB, METER SOCKET
Removable meter socket hub. Ideal for use when installing meter sockets with overhead service.
View Details
Removable meter socket hub. Ideal for use when installing meter sockets with overhead service.

1-1/2" HUB
Removable meter socket hub. Ideal for use when installing meter sockets with overhead service.
View Details
Removable meter socket hub. Ideal for use when installing meter sockets with overhead service.

1-1/4" METER SOCKET HUB
Removable meter socket hub. Ideal for use when installing meter sockets with overhead service.
View Details
Removable meter socket hub. Ideal for use when installing meter sockets with overhead service.

1-1/4" ALUM BR CONDUIT HUB
Conduit hub compatible with BR series equipment. Ideal to use to create a watertight seal between the meter breaker panel and the conduit holding the wire.
View Details
Conduit hub compatible with BR series equipment. Ideal to use to create a watertight seal between the meter breaker panel and the conduit holding the wire.

200A 30/60 LOAD CENTER VALUE PAC
Single-phase, plug-on neutral, main circuit breaker load center. Suitable for indoor use only. Includes NEMA Type 3R cover. Contains the following breakers: (5) BR120 and (1) BR230.
View Details
Single-phase, plug-on neutral, main circuit breaker load center. Suitable for indoor use only. Includes NEMA Type 3R cover. Contains the following breakers: (5) BR120 and (1) BR230.

60A SWITCH SAFETY OUTDOOR
Fusible general-duty safety switch designed for residential and commercial applications where economy is a prime consideration. Typical uses are heating, lighting, air conditioning and appliances. Cartridge fuses not included. 3-wire, 2-pole, solid neutral, 240V AC.
View Details
Fusible general-duty safety switch designed for residential and commercial applications where economy is a prime consideration. Typical uses are heating, lighting, air conditioning and appliances. Cartridge fuses not included. 3-wire, 2-pole, solid neutral, 240V AC.

30A SAFETY SWITCH
Fusible general-duty safety switch designed for residential and commercial applications where economy is a prime consideration. Typical uses are heating, lighting, air conditioning and appliances. Cartridge fuses not included. 3-wire, 2-pole, solid neutral, 240V AC.
View Details
Fusible general-duty safety switch designed for residential and commercial applications where economy is a prime consideration. Typical uses are heating, lighting, air conditioning and appliances. Cartridge fuses not included. 3-wire, 2-pole, solid neutral, 240V AC.

3000L FLDB LED WORKLIGHT
3000L FLDB LED WORKLIGHT
View Details
3000L FLDB LED WORKLIGHT

30A SAFETY SWITCH
Fusible general-duty safety switch designed for residential and commercial applications where economy is a prime consideration. Typical uses are heating, lighting, air conditioning and appliances. Cartridge fuses not included. 3-wire, 2-pole, solid neutral, 240V AC.
View Details
Fusible general-duty safety switch designed for residential and commercial applications where economy is a prime consideration. Typical uses are heating, lighting, air conditioning and appliances. Cartridge fuses not included. 3-wire, 2-pole, solid neutral, 240V AC.

30A SP CIRCUIT BREAKER
Single pole type. 120/240V. Carded.
View Details
Single pole type. 120/240V. Carded.

GROUND BAR KIT
Mount grounding bar to back of box using 2 screws and 2 holes provided. Mounting screw locations (mounting screws included). For BR series panels.
View Details
Mount grounding bar to back of box using 2 screws and 2 holes provided. Mounting screw locations (mounting screws included). For BR series panels.

GROUND BAR KIT, 10 CIRCUITS
Mount grounding bar to back of box using 2 screws and 2 holes provided. Mounting screw locations (mounting screws included). For BR series panels.
View Details
Mount grounding bar to back of box using 2 screws and 2 holes provided. Mounting screw locations (mounting screws included). For BR series panels.

200A METER SOCKET
Professional, preferred quality meter socket for 200A continuous 600V, 3-wire, single phase service. Outdoor, ringless, 4-jaw, overhead or underground service design with ground wire connector and no bypass. High-quality G90 steel, polyester-coated enclosure. No hub included. 12 In. x 16 In. x 6 In. UL (Underwriter's Laboratories) listed.
View Details
Professional, preferred quality meter socket for 200A continuous 600V, 3-wire, single phase service. Outdoor, ringless, 4-jaw, overhead or underground service design with ground wire connector and no bypass. High-quality G90 steel, polyester-coated enclosure. No hub included. 12 In. x 16 In. x 6 In. UL (Underwriter's Laboratories) listed.

GROUND BAR KIT, 5 CIRCUITS
Mount grounding bar to back of box using 2 screws and 2 holes provided. Mounting screw locations (mounting screws included). For BR series panels.
View Details
Mount grounding bar to back of box using 2 screws and 2 holes provided. Mounting screw locations (mounting screws included). For BR series panels.

125A METER SOCKET
Professional, preferred quality meter socket for up to 125A continuous 600V, 3-wire, single phase service. Outdoor, ringless, 4-jaw, overhead or underground service design with ground wire connector and no bypass. High-quality G90 steel, polyester-coated enclosure. No hub included. 9 In. x 12 In. x 5 In. UL (Underwriter's Laboratories) listed.
View Details
Professional, preferred quality meter socket for up to 125A continuous 600V, 3-wire, single phase service. Outdoor, ringless, 4-jaw, overhead or underground service design with ground wire connector and no bypass. High-quality G90 steel, polyester-coated enclosure. No hub included. 9 In. x 12 In. x 5 In. UL (Underwriter's Laboratories) listed.

15A SP CIRCUIT BREAKER****
Single pole type. 120/240V. Carded.
View Details
Single pole type. 120/240V. Carded.

20A TWIN CIRCUIT BREAKER
Interchangeable circuit breaker. Compatible with American Switch, Arrow-Hart, Bryant, Challenger, Cutler-Hammer, Electricenter, Frank Adams, GTE Sylvania, General Switch, General Electric, Gould, Montgomery Ward, Siemens, Murray, Thomas & Betts, and Westinghouse load centers.
View Details
Interchangeable circuit breaker. Compatible with American Switch, Arrow-Hart, Bryant, Challenger, Cutler-Hammer, Electricenter, Frank Adams, GTE Sylvania, General Switch, General Electric, Gould, Montgomery Ward, Siemens, Murray, Thomas & Betts, and Westinghouse load centers.

FIXT QTZ 2-LIGHT************
1000-watt, 120-volt halogen twin head utility work light telescopes up to 42 inches tall and uses locking nuts for easy adjustment. Hinged face, tempered safety glass, and Shadow Fighter grill. (2) 500-watt halogen bulbs included. 16,000-lumen output. Safety yellow. UL (Underwriters' Laboratories) and CUL (Underwriters' Laboratories of Canada) listed.
View Details
1000-watt, 120-volt halogen twin head utility work light telescopes up to 42 inches tall and uses locking nuts for easy adjustment. Hinged face, tempered safety glass, and Shadow Fighter grill. (2) 500-watt halogen bulbs included. 16,000-lumen output. Safety yellow. UL (Underwriters' Laboratories) and CUL (Underwriters' Laboratories of Canada) listed.

BRZ D2D 1HDSQ FLD LIGHT
BRZ D2D 1HDSQ FLD LIGHT
View Details
BRZ D2D 1HDSQ FLD LIGHT

30A PLUG FUSE
Medium-duty time delay, loaded link rejection base SL fuse for residential motor circuits. Ideal for use in kitchens, garages, utility room circuits, or any circuit that contains electric motors, relays, or solenoids. Porcelain threads (Tamper proof base) prevent a larger amp fuse from being used. Extra large clear window makes it easy to see if fuse is blown. 125V AC, 10,000 A.I.C. UL (Underwriter's Laboratories) listed.
View Details
Medium-duty time delay, loaded link rejection base SL fuse for residential motor circuits. Ideal for use in kitchens, garages, utility room circuits, or any circuit that contains electric motors, relays, or solenoids. Porcelain threads (Tamper proof base) prevent a larger amp fuse from being used. Extra large clear window makes it easy to see if fuse is blown. 125V AC, 10,000 A.I.C. UL (Underwriter's Laboratories) listed.

20A PLUG FUSE
Medium-duty time delay, loaded link rejection base SL fuse for residential motor circuits. Ideal for use in kitchens, garages, utility room circuits, or any circuit that contains electric motors, relays, or solenoids. Porcelain threads (Tamper proof base) prevent a larger amp fuse from being used. Extra large clear window makes it easy to see if fuse is blown. 125V AC, 10,000 A.I.C. UL (Underwriter's Laboratories) listed.
View Details
Medium-duty time delay, loaded link rejection base SL fuse for residential motor circuits. Ideal for use in kitchens, garages, utility room circuits, or any circuit that contains electric motors, relays, or solenoids. Porcelain threads (Tamper proof base) prevent a larger amp fuse from being used. Extra large clear window makes it easy to see if fuse is blown. 125V AC, 10,000 A.I.C. UL (Underwriter's Laboratories) listed.

FUSE PLUG BP/SL15
Medium-duty time delay, loaded link rejection base SL fuse for residential motor circuits. Ideal for use in kitchens, garages, utility room circuits, or any circuit that contains electric motors, relays, or solenoids. Porcelain threads (Tamper proof base) prevent a larger amp fuse from being used. Extra large clear window makes it easy to see if fuse is blown. 125V AC, 10,000 A.I.C. UL (Underwriter's Laboratories) listed.
View Details
Medium-duty time delay, loaded link rejection base SL fuse for residential motor circuits. Ideal for use in kitchens, garages, utility room circuits, or any circuit that contains electric motors, relays, or solenoids. Porcelain threads (Tamper proof base) prevent a larger amp fuse from being used. Extra large clear window makes it easy to see if fuse is blown. 125V AC, 10,000 A.I.C. UL (Underwriter's Laboratories) listed.

MAIN LUG LOAD CENTER
Main lug load center designed for service entrance equipment. Main lugs only. Single-phase, 3-wire, flush or surface mount. Solid neutral bar and cover included. Optional ground bar kits must be ordered separately. Load centers that acceptBD and BQ type circuit breakers have a notched bus bar. UL (Underwriter's Laboratories) listed.
View Details
Main lug load center designed for service entrance equipment. Main lugs only. Single-phase, 3-wire, flush or surface mount. Solid neutral bar and cover included. Optional ground bar kits must be ordered separately. Load centers that acceptBD and BQ type circuit breakers have a notched bus bar. UL (Underwriter's Laboratories) listed.

DIGITAL COUNTDOWN TIMER
DIGITAL COUNTDOWN TIMER
View Details
DIGITAL COUNTDOWN TIMER

3PK REMOTE OUTLETS
Wireless remote with 3 individual outlets. On/off push-buttons control lamps, fans, holiday lights, and more. Ideal for holiday decorations, the mobility-impaired, or for 1-touch convenience. Features tool-free set up and easy operation. Space saving grounded outlet on the bottom of each receiver.
View Details
Wireless remote with 3 individual outlets. On/off push-buttons control lamps, fans, holiday lights, and more. Ideal for holiday decorations, the mobility-impaired, or for 1-touch convenience. Features tool-free set up and easy operation. Space saving grounded outlet on the bottom of each receiver.

70A MAIN LUG LOAD CENTER
Main lug load center designed for service entrance equipment. Main lugs only. Single-phase, 3-wire, flush or surface mount. Solid neutral bar and cover included. Optional ground bar kits must be ordered separately. Load centers that acceptBD and BQ type circuit breakers have a notched bus bar. UL (Underwriter's Laboratories) listed.
View Details
Main lug load center designed for service entrance equipment. Main lugs only. Single-phase, 3-wire, flush or surface mount. Solid neutral bar and cover included. Optional ground bar kits must be ordered separately. Load centers that acceptBD and BQ type circuit breakers have a notched bus bar. UL (Underwriter's Laboratories) listed.

BLK MINI STK SOLAR LIGHT
Solar powered mini stake light recharges by sunlight and automatically turns On at night. Bright white LED technology, lights up to 10 hours with fully charged batteries (batteries included). Uses (1) AAA 1.2V NiCd rechargeable battery.
View Details
Solar powered mini stake light recharges by sunlight and automatically turns On at night. Bright white LED technology, lights up to 10 hours with fully charged batteries (batteries included). Uses (1) AAA 1.2V NiCd rechargeable battery.

*CPR MINI STK SOLAR LIGHT
Solar powered mini stake light recharges by sunlight and automatically turns On at night. Bright white LED technology, lights up to 10 hours with fully charged batteries (batteries included). Uses (1) AAA 1.2V NiCd rechargeable battery.
View Details
Solar powered mini stake light recharges by sunlight and automatically turns On at night. Bright white LED technology, lights up to 10 hours with fully charged batteries (batteries included). Uses (1) AAA 1.2V NiCd rechargeable battery.